LVL Bearers Sizing Reference Guide (Australia)
Timber grades, section sizes and questions for professional review. No allowable span values are provided; consult official sources and a qualified designer.
Verify against AS 1684.2
All numeric span values for bearers must be confirmed against the official AS 1684.2 (non-cyclonic) or AS 1684.3 (cyclonic) table for your wind classification and load condition. The information on this page is a sizing starting point for builders, owner-builders and homeowners — it is not a substitute for the standard or for engineer sign-off on permitted work.
General roof terminology
The diagram below illustrates a pitched roof, not an application-specific design. It shows where roof members sit in a typical pitched roof, and what "span" and "spacing" mean when you read a sizing table.
As an Amazon Associate, RoofingTimber.com earns from qualifying purchases. Links to products are affiliate links — we may earn a small commission at no extra cost to you.
Construction Master Pro Calculator (4065)
Works in feet-inches and metric, solves rafter lengths, rise/run, angles and stair layouts. A framer's favourite for roof maths.
About LVL (Laminated Veneer Lumber)
A grade label alone does not establish suitability. Confirm the actual product, grading evidence and intended use with a qualified designer.
Common species: Radiata Pine veneer, Hardwood veneer.
About bearers as a structural member
Bearers run at right angles under the joists, collecting the joist loads and carrying them to posts, stumps or piers. A bearer is sized for two things at once — the tributary load from the joist span it supports, and its own span between supports — so bearer tables are read against both figures.
Common LVL bearer sizes used in Australia
Section sizes most commonly stocked and specified for LVL bearers in Australian residential construction. Maximum allowable spans for each section must be confirmed against the AS 1684.2 bearer table.
| Section size (mm) | Typical spacing (mm) | Max single span (m) |
|---|---|---|
| 140×45 | 450 | verify against AS 1684.2 Table |
| 140×45 | 600 | verify against AS 1684.2 Table |
| 190×45 | 450 | verify against AS 1684.2 Table |
| 190×45 | 600 | verify against AS 1684.2 Table |
| 240×45 | 450 | verify against AS 1684.2 Table |
| 240×45 | 600 | verify against AS 1684.2 Table |
| 240×63 | 450 | verify against AS 1684.2 Table |
| 240×63 | 600 | verify against AS 1684.2 Table |
| 240×90 | 450 | verify against AS 1684.2 Table |
| 240×90 | 600 | verify against AS 1684.2 Table |
- 140×45
- Typical spacing (mm)
- 450
- Max single span (m)
- verify against AS 1684.2 Table
- 140×45
- Typical spacing (mm)
- 600
- Max single span (m)
- verify against AS 1684.2 Table
- 190×45
- Typical spacing (mm)
- 450
- Max single span (m)
- verify against AS 1684.2 Table
- 190×45
- Typical spacing (mm)
- 600
- Max single span (m)
- verify against AS 1684.2 Table
- 240×45
- Typical spacing (mm)
- 450
- Max single span (m)
- verify against AS 1684.2 Table
- 240×45
- Typical spacing (mm)
- 600
- Max single span (m)
- verify against AS 1684.2 Table
- 240×63
- Typical spacing (mm)
- 450
- Max single span (m)
- verify against AS 1684.2 Table
- 240×63
- Typical spacing (mm)
- 600
- Max single span (m)
- verify against AS 1684.2 Table
- 240×90
- Typical spacing (mm)
- 450
- Max single span (m)
- verify against AS 1684.2 Table
- 240×90
- Typical spacing (mm)
- 600
- Max single span (m)
- verify against AS 1684.2 Table
Sizing guidance and AS 1684 compliance notes
Project-specific sizing guidance is withheld pending qualified review. Ask a qualified designer to assess loads, supports, connections, exposure and the applicable current standard. No size, spacing or span on this reference page is an approved specification.
How to read a LVL bearer span table
- Determine your required span — the clear distance between the supports the bearer will sit on.
- Note your spacing — typically 450 or 600 mm centres.
- Identify your wind classification (N1–N4 non-cyclonic, C1–C4 cyclonic) and load category.
- Look up the AS 1684.2 bearer table for LVL and read off the smallest section size whose maximum span exceeds your required span.